call

Call us now

08037736332

Plate Type Heat Exchanger
Plate Type Heat Exchanger

Plate Type Heat Exchanger

MOQ : 1 Piece

Plate Type Heat Exchanger Specification

  • Thickness
  • Plate thickness: 0.5 mm to 0.7 mm
  • Number of Pipe
  • Not Applicable (uses plates, not pipes)
  • Diameter
  • Connection Diameter: 32 mm to 100 mm
  • Max. Capacity
  • Up to 500 kW (varies by application)
  • Max Pressure
  • 16 bar
  • Air Volume
  • N/A (liquid-liquid heat exchanger)
  • Temperature
  • -20C to 180C (operating range)
  • Condition
  • New
  • Structure
  • Frame-and-plate, Gasketed design
  • Liquid Flow Rate
  • 1~150 m3/h (varies as per design)
  • Working Presssure
  • Up to 16 bar
  • Power
  • Not Applicable (Passive device)
  • Weight
  • Approx. 70-150 kg (varies with model)
  • Dimensions
  • Length 800-1200 mm, Width 500-1000 mm, Height 800-1500 mm (approx.)
  • Application
  • Milk pasteurization, HVAC, chemical industry, food processing
  • Plate Design
  • Corrugated, high turbulence for enhanced efficiency
  • Maintenance
  • Easy disassembly for cleaning and servicing
  • Gasket Material
  • EPDM/NBR/Viton
  • Number of Pipe
  • Multiple connections; specific to configuration
  • Plate Material
  • Stainless Steel 304/316
  • Heat Exchange Area
  • 2-20 m2 (as per model size)
  • Frame Material
  • Stainless Steel with protective coating
  • Connection Type
  • Threaded/Flanged
 

Plate Type Heat Exchanger Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

About Plate Type Heat Exchanger



Get exceptional thermal performance with our plate type heat exchanger, now available in a grandiose clearance event ending soon! Featuring potent chevron-patterned plates crafted from stainless steel 304/316 or titanium, this superlative device ensures maximum efficiency for milk chillers, HVAC systems, chemical processing, food and beverage, and more. Benefit from a frame-and-plate gasketed structure, easy maintenance, superlative sealing (NBR/EPDM/Viton), compact footprint, and the ability to handle up to 500 kW. Don't miss out-stock is ending soon on this reliable, new, passive powerhouse!

Diverse Usage & Applications for Every Industry

This plate type heat exchanger is expertly engineered for potent heat exchange across a grandiose range of applications. It is well-suited for milk chillers, hydraulic oil cooling, HVAC systems, chemical processing, sugar mills, and food & beverage industries. Its compact yet efficient design enables floor-mounted installation, making it superlative for both industrial and commercial use. These exchangers ensure efficient process heating or cooling in environments where reliability and easy maintenance are paramount.


Expansive Domestic Market & Smooth Dispatch Process

Our plate type heat exchangers are primarily dispatched to clients across India's leading industrial markets. Handed over via our designated FOB port, products are delivered promptly upon order confirmation. We offer flexible sample policies, allowing proposals of nominal sample amounts to interested clients. The entire process-from proposal acceptance to dispatch-is professionally managed to guarantee swift and secure installation at your facility.


FAQ's of Plate Type Heat Exchanger:


Q: How do I select the correct plate material for my fluid application?

A: Selecting the appropriate plate material-stainless steel or titanium-depends on the fluid's compatibility. Titanium is best suited for highly corrosive fluids, while stainless steel is excellent for water, glycol, and non-aggressive chemicals.

Q: What is the process for cleaning and maintaining the plate type heat exchanger?

A: Maintenance is simplified thanks to the gasketed, frame-and-plate design. Simply dismantle the unit using support brackets, clean and inspect the plates and gaskets, and reassemble for continued potent performance.

Q: When should I consider replacing the gaskets on the unit?

A: Gaskets should be inspected periodically, especially if exposed to high temperatures or aggressive fluids. Replacement is recommended whenever you notice signs of hardening, wear, or leakage to maintain optimal sealing efficiency.

Q: Where can these plate type heat exchangers be installed?

A: These heat exchangers are floor-mounted with support brackets, making them suitable for installation in industrial plants, processing facilities, commercial HVAC rooms, and any place requiring controlled heat exchange.

Q: What are the benefits of using a chevron plate pattern?

A: Chevron patterns create turbulence as fluids flow over the plates, significantly increasing the heat transfer coefficient and enhancing the exchanger's overall efficiency-making the system both compact and powerful in thermal performance.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Heat Exchanger Category

Heat Exchangers For For Power Plant

Heat Exchangers For For Power Plant

Minimum Order Quantity : 1 Piece

Working Presssure : 10 to 250 bar (approx. 1450 3625 psi)

Max Pressure : Design up to 250 bar

Structure : Other, Shell and Tube Type, Horizontal Mounting

Condition : New

Temperature : Other, Design temperature: 30C to +450C

Tube Heat Exchanger

Tube Heat Exchanger

Minimum Order Quantity : 1 Piece

Working Presssure : Up to 35 bar (can be customized)

Max Pressure : 35 bar

Structure : Other, Shell & Tube

Condition : New

Temperature : Other, Up to 400C

Carbon Steel Heat Exchanger

Carbon Steel Heat Exchanger

Minimum Order Quantity : 1 Piece

Working Presssure : 350 Bar

Max Pressure : 350 Bar

Structure : Other, Shell and Tube

Condition : New



arrow